April 17, 1996

SEGA Service Bulletin

"This Bulletin applies to the Manx TT &Motor Raid Deluxe Machines Only "

Problem: Motor Feed-Back is incorrect or non-existent. Game may fail Power On Check of the Motor System ( Error displayed on power up ).

Cause: Wire Protect Bracket rubbing on bottom side of floor panel. This is caused by it being bent upwards. Wiring Service loop may be responsible, if not properly secured.
April 17, 1996

Correction: Using the drawing on page 2 as a guide, install new Wire Protect Bracket and wire harness dressing and ties. The instructions are as follows:

For further information. contact your Sega Distributor, or Sega Technical Services at (415) 802-1750 7:30am to 4:00pm Pacific.


Back to list of Manx TT bulletins or manual.